11 Mechanical installation
11.4

ASSA ABLOY SW300 inverse installation with PUSH arm system

Remove the microswitch lever (1), but not the micro switch (2). Remove also the stop arm (3).
Note! Set dip switch INV to ON for Inverse operation, see
Spring pre-tension should not be more than 7 mm (measured between the washer and the adjust-
ment nut).
Closing torque CLTQ can be adjusted to maximum 75%, to avoid motor to be overheated.
Follow step
ator is turned 180° so the "INVERSE" text on the operator is visible and do not make step
.
Open the door to fully open
position. Tighten the adaptor
54
to
in section
PUSH arm system
fixing screw.
Issue 2021-02-04
1
Microswitch lever
2
Micro switch
3
Stop arm
12.1.1
on page 64.
on page 41, with the difference that the oper-
If necessary, adjust by moving the adaptor one step at a time.
and
50 Nm
1007913-en-20.0