13 Start-up
13.6
Connection of activation units and accessories
See sensor manuals for mounting and adjustments. Protective device shall comply with EN 12978.
Door mounted
When sensors are used in order to avoid contact with the door leaf it is required that the presence detect sensor
and the presence impulse sensor fulfills Performance Level = c according to EN ISO 13849-1. These sensors shall
also be monitored (tested) by ASSA ABLOY SW300 and ASSA ABLOY SW150 door operators.
** Note! When using the quick connector, opening
and closing side will be reversed.
Inner impulse
Outer impulse
Key Impulse
Presence impulse
Presence detection
Off
Kill impulse NO
Kill impulse NC, fire alarm, smoke detector
Fire alarm reset
External fire alarm (Select 12, 24 or 48 VDC, see page 87)
78
Activation
PS-4C
Fire
sensor
alarm
Issue 2021-02-04
Configue sensor SP33-M:
DIP A7 to ON (for primary sensor)
DIP B4 to ON for presence impulse
DIP B4 to OFF for presence detection
A
Brown
B
Yellow
C
Pink
D
Violet
E
White
F
Blue
G
Red
H
Green
I
Black
J
Grey
1007913-en-20.0