Technical Specifications - Assa Abloy SW300 Installation And Service Manual

Swing door operator
Hide thumbs Also See for SW300:
Table of Contents

Advertisement

4

Technical specifications

Ensure that the door operator with technical specification below is suitable for the installation.
Manufacturer:
Address:
Type:
Mains supply:
Power consumption:
Auxiliary voltage:
Mains fuse F1, F2:
Door size:
Electro-mechanical locking
device:
Door opening angle:
Opening time (0° - 80°):
Closing time (90° - 10°):
HOLD open time:
Ambient temperature:
Relative humidity:
Drive unit weight:
Class of protection:
Degree of protection, con-
trol actuators:
Approvals:
Complies with: EN 16005, EN 60335-2-103, EN 1634-1
1007913-en-20.0
ASSA ABLOY Entrance Systems AB
Lodjursgatan 10, SE-261 44 Landskrona, Sweden
ASSA ABLOY SW300 and ASSA ABLOY SW150
100-240 V AC +10/-15%, 50/60 Hz, mains fuse max 10A (building
installation)
Note! The mains supply shall be installed with protection and an
all-pole mains switch with isolating capability of Category III, at least
3 mm between contacts, shall be installed according to local regu-
lations. These articles are not provided with the door.
Max. 300 W
24 V DC, max. 700 mA (max. 1000 mA including lock)
2 x T 6,3 AH/250 V
PUSH arm system; size 4 - 7
PULL arm system; size 4 - 6
2
For PUSH = 140 kgm
for ASSA ABLOY SW300 and
2
70 kgm
for ASSA ABLOY SW150
2
For PULL = 80 kgm
for ASSA ABLOY SW300 and
2
40 kgm
for ASSA ABLOY SW150
Inertia = Door weight x (Door width)
Selectable: 12 V DC, max. 1200 mA or 24 V DC, max. 600 mA
PUSH arm: 80° - 110°, with reveal 0 - 367 mm
PULL arm and Sliding PUSH arm: 80° - 110°, with reveal -20 - 130
mm
Variable between 2.5 - 12 s
Note! If opening time is set to below 3 s, it does not meet the require-
ments of LOW ENERGY, safety sensors must be installed.
Variable between 4 - 12 s
Note! If opening time is set to below 3 s, it does not meet the require-
ments of LOW ENERGY, safety sensors must be installed.
1.5 - 30 s
-20 °C to +45 °C
Max. 95%
7.6 kg
IP20
IP54
Third party approvals from established certification organizations
valid for safety in use, see Declaration of Conformity.
Issue 2021-02-04
4 Technical specifications
2
/ 3
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw150

Table of Contents