Finalize Installation; General Electrical Information - Assa Abloy Norton D6021 Series Installation Instructions Manual

Table of Contents

Advertisement

D6021/D6031 Double Unit Series (Push Side) Power Operator
Attach Covers to finalize installation
1.
Align cut-outs in each cover to corresponding
pinion shafts. (Figure 30)
2.
Slide covers onto units using end caps and
union spacers as guides.
NOTE: Verify all wiring and sheet metal
guards are inside cover.
3.
Snap covers securely to backplates. Pull on
covers to verify they are secure.
NOTE: If cover will not securely snap onto
backplate, verify backplate is not warped or
twisted. Additional support or shimming may
be required. See Sections A & B under Prepare
Frame and Door.
Power inputs at power input connection and
power output contacts must be made with
copper wire only.
Maximum wire size:
12 AWG at power input connection
14 AWG at all other terminals.
Power input at terminals LINE and NEUTRAL
must be 120VAC at 60 Hz (+10%, -15%).
Copyright © 2019-2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1030-020 Rev 6 11/20
Pinion Shaft Cut-out
Figure 30
WARNING: Make sure no wiring is loose or can be
caught by cover when it is snapped into place.

General Electrical Information

Maximum current draw from auxiliary devices is
1.3 amps.
All wiring and connections use standard wiring
practice conforming with local wiring codes.
Labeled fire or smoke barrier door assemblies
require 120VAC 60Hz power input be supplied
through normally closed alarm contacts of the
alarm system / alarm panel.
Pinion Shaft Cut-out
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Norton d6031 seriesNorton d6001bp-38-rhNorton d6001bp-40-rhNorton d6001bp-38-lhNorton d6001bp-44-rhNorton d6001bp-40-lh ... Show all

Table of Contents