[Source:]Voltage[:Level][:Immediate][:Amplitude]; [Source:]Voltage:minimum[:Level] - ITech IT6500C Series Manual

Highpowered and programmable power supply
Hide thumbs Also See for IT6500C Series:
Table of Contents

Advertisement

Arguments
MINimum|MAXimum|NRf
Unit
S
Reset Value
0.2
Example
CURR:PROT:DEL 6.0
Query syntax
[SOURce:]CURRent:PROTection:DELay? [MINimum|MAXimum]
Returns
NRf

[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]

This command is used to set output Voltage value.
Command syntax
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]
<MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
V
Reset Value
0.0
Example
VOLT 60.0
Query syntax
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returns
NRf

[SOURce:]VOLTage:MINimum[:LEVel]

This command is used to set minimum value of voltage.