Load:power:protection[:Level]; Load:power:protection:delay - ITech IT6500C Series Manual

Highpowered and programmable power supply
Hide thumbs Also See for IT6500C Series:
Table of Contents

Advertisement

Returns
0|1

LOAD:POWer:PROTection[:LEVel]

This command is used to set power value of load OPP.
Command syntax
LOAD:POWer:PROTection[:LEVel] <MINimum|MAXimum|DEFault|NRf>
Arguments
MINimum|MAXimum|DEFault|NRf
Unit
W
Reset Value
MAXimum
Example
LOAD:POW:PROT MAX
Query syntax
LOAD:POWer:PROTection[:LEVel]? [MINimum|MAXimum|DEFault]
Returns
NRf

LOAD:POWer:PROTection:DELay

This command is used to set delay time for load OPP.
Command syntax
LOAD:POWer:PROTection:DELay <MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
S
Reset Value
0.5
Example
LOAD:POW:PROT:DEL 0.04
Copyright© Itech Electronics Co., Ltd.
Load Related Command(IT6500C)