Chapter11 Wave Operation Command

SEQuence:EDIT

This command is used to select the wave file to be edited.
Command syntax
SEQuence:EDIT <MINimum|MAXimum|1~100>
Arguments
MINimum|MAXimum|<1~100>
Example
SEQ:EDIT 3
Query syntax
SEQuence:EDIT? [MINimum|MAXimum]
Returns
NR1

SEQuence:RECall

This command is used to recall a wave file.
Command syntax
SEQuence:RECall <NR1>
Arguments
MINimum|MAXimum|<1-100>
Example
SEQ:REC 1
Query syntax
SEQ:REC?
Returns
NR1

SEQuence:STEP:COUNt

This command is used to edit the step count of wave file.
Command syntax
SEQuence:STEP:COUNt <1~10>