Query syntax
LOAD:SELection?
Returns
<CRD>
LOAD:NUMBer[:EXTernal]
This command is used to set the number of external loads. When IT6500C
Series power supply uses external load function, you need to set the number of
external loads.
Command syntax
LOAD:NUMBer[:EXTernal] <1~3>
Arguments
<1~3>
Reset Value
1
Example
LOAD:NUMB 1
Query syntax
LOAD:NUMBer[:EXTernal]?
Returns
NR1
LOAD:CURRent[:LEVel][:IMMediate][:AMPLitude]
This command is used to set current of load.
Command syntax
LOAD:CURRent[:LEVel][:IMMediate][:AMPLitude] <MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
A
Reset Value
5 (The reset value of different models are different)
Example
LOAD:CURR 2.0
Copyright© Itech Electronics Co., Ltd.
Load Related Command(IT6500C)
51