Carwave:iso16750:Load:dump[:State]; Carwave:iso16750:Load:dump:test[:Mode] - ITech IT6500C Series Manual

Highpowered and programmable power supply
Hide thumbs Also See for IT6500C Series:
Table of Contents

Advertisement

Query syntax
CARWave:ISO21848:STARtup:PROFile[:STATe]?
Returns
<CRD>

CARWave:ISO16750:LOAD:DUMP[:STATe]

This command is used to simulate load dump wave of car.
Command syntax
CARWave:ISO16750:LOAD:DUMP <bool>
Arguments
ON|OFF|1|0
Reset Value
0
Example
CARW:ISO16750:LOAD:DUMP 1
Query syntax
CARWave:ISO16750:LOAD:DUMP?
Returns
0|1

CARWave:ISO16750:LOAD:DUMP:TEST[:MODe]

This command is used to select the test mode of load dump wave of car.
Command syntax
CARWave:ISO16750:LOAD:DUMP:TEST <AMODe|BMODe >
Arguments
AMODe|BMODe
Reset Value
AMODe
Example
CARW:ISO16750:LOAD:DUMP:TEST AMOD
Query syntax
CARWave:ISO16750:LOAD:DUMP:TEST?
Copyright© Itech Electronics Co., Ltd.