Command syntax
CARWave:LV124:E12 <bool>
Arguments
ON|OFF|1|0
Reset Value
0
Example
CARWave:LV124:E12 1
Query syntax
CARWave:LV124:E12?
Returns
0|1
CARWave:LV124:E12:DELTAU[:LEVel]
This command is used to set voltage drop ΔU value of LV124 E12.
Command syntax
CARWave:LV124:E12:DELTAU < value >
Arguments
MINimum|MAXimum|NR3
Reset Value
0.0
Example
CARWave:LV124:E12:DELTAU 2
Query syntax
CARWave:LV124:E12:DELTAU?
Returns
NR3
Copyright© Itech Electronics Co., Ltd.