[SOURce:]POWer:PROTection:STATe

This command is used to set over power protection state.
Command syntax
[SOURce:]POWer:PROTection:STATe<bool>
Arguments
ON|OFF|1|0
Reset Value
1
Example
POW:PROT:STAT 1
Query syntax
[SOURce:]POWer:PROTection:STATe?
Returns
0|1

[SOURce:]POWer:PROTection[:LEVel]

This command is used to set power value for over power protection.
Command syntax
[SOURce:]POWer:PROTection[:LEVel] <MINimum|MAXimum|DEFault|NRf>
Arguments
MINimum|MAXimum|DEFault|NRf
Unit
w
Query syntax
[SOURce:]POWer:PROTection[:LEVel]? [MINimum|MAXimum|DEFault]
Returns
NRf

[SOURce:]POWer:PROTection:DELay

This command is used to set delay time for over power protection.
Command syntax
[SOURce:]POWer:PROTection:DELay <MINimum|MAXimum|NRf>