Carwave:sae[:Test]:5:Test[:Mode]; Carwave:sae[:Test]:5[:Voltage]:Un[:Level] - ITech IT6500C Series Manual

Highpowered and programmable power supply
Hide thumbs Also See for IT6500C Series:
Table of Contents

Advertisement

Query syntax
CARWave:SAE:5?
Returns
0|1

CARWave:SAE[:TEST]:5:TEST[:MODe]

This command is used to select test mode of SAEJ1113-11 TEST 5.
Command syntax
CARWave:SAE:5:TEST <AMODe|BMODe>
Arguments
AMODe|BMODe
Reset Value
AMODe
Example
CARWave:SAE:5:TEST AMODe
Query syntax
CARWave:SAE:5:TEST?
Returns
<CRD>

CARWave:SAE[:TEST]:5[:VOLTage]:UN[:LEVel]

This command is used to set Un of SAEJ1113-11 TEST 5.
Command syntax
CARWave:SAE:5:UN < value >
Arguments
MINimum|MAXimum|NR3
Reset Value
MINimum
Example
CARWave:SAE:5:UN 70
Query syntax
CARWave:SAE:5:UN?
Copyright© Itech Electronics Co., Ltd.