1 Introduction
DN
50
2"
80
3"
100
4"
24
150
6"
200
8"
250
10"
300
12"
400
16"
500
20"
600
24"
Note
When flange seals which protrude into the pipeline are used for turbine me-
ters, the measuring accuracy can be influenced negatively. Ensure that the
flange seals do not protrude beyond the seal surfaces into the pipeline.
Danger
Gas escape due to incorrect seal
If incorrect flange seals are used for the assembly of turbines, an explosive
gas mixture can form due to leaks.
Danger of poisoning and explosion!
In addition, the stress on the flange is increased to an impermissible level
when tightening the thread bolts.
Ensure secure fastening/attachment of the TME400 during assembly in order
to avoid crushing. Ensure that you keep your fingers (or other body parts)
away from these openings and gaps when pulling the flanges together.
Manual TME400-VMF · EN07 · December, 7
ANSI 300
d1
d2
d3
51
69.9
85.9
81
101.6
120.7
106.4
127.0
149.4
157.2
182.6
209.6
215.9
233.4
263.7
268.3
287.3
317.5
317.5
339.9
374.7
400
422.4
463.6
500
525.5
577.9
603.3
628.7
685.8
th
2020
PN 64
d1
d2
d3
54
66
84
86
95
119
108
120
144
162
174
200
213
225
257
267
279
315
318
330
366
414
426
466
518
530
574
618
630
674
ANSI 600
d1
d2
51
69.9
85.9
81
101.6
120.7
106.4
120.7
149.4
157.2
174.8
209.6
215.9
225.6
263.7
268.3
274.6
317.5
317.5
327.2
374.7
400
412.8
463.6
500
520.7
577.9
603.3
628.7
685.8

Hide quick links: