Danger
The battery must only be replaced in a non-explosive atmosphere. Ensure
that the electronics are supplied with adequate ventilation with fresh air.
Note
The battery can be changed during operation.
All readings of the counter(s) and all counting parameters are retained.
After changing the battery, the current time and date must be entered
again (coordinates X01 and X02; see chapter 4.3.3.6 Archive ). In addition,
the battery change must be indicated in coordinate G25. This updates
the battery change date and sets the operating hours G26 to 0 and the
battery capacity G24 to 100 %.
The current flow rate value is not stored during the change because
there is no additional battery buffering.
Figure 10: Battery holder
Manual TME400-VMF · EN07 · December, 7
3 TME400
49
th
2020