Hot start level
Hot start time
Minilog
Downslope
Post gas
Adjustable parameters in spot welding:
Parameter
Pre gas
Upslope
Downslope
Post gas
Adjustable parameters in MicroTack welding:
Parameter
Pre gas
Post gas
Adjustable parameters in AC mode:
Parameter
Balance
AC Frequency
Adjustable parameters in Pulse mode:
Parameter
Pulse current
Pulse ratio
Base current
Pulse frequency
Pulse frequency
© Kemppi
Min/Max = -80 % ... +100 %, 1 % step (Default =
Off), Value '0' = Hot start off
Min/Max = 0.1 s ... 9.9 s, 0.1 s step (Default = 1.2 s)
Min/Max = -99 % ... +125 %, 1 % step (Default =
Off), Value '0' = Minilog off
Min/Max = 0.0 s ... 15.0 s, 0.1 s step (Default = 0.1 s)
Min/Max = 0.0 s ... 30.0 s, Auto, 0.1 s step (Default =
Auto)
Value
Min/Max = 0.0 s ... 9.9 s, Auto, 0.1 s step
(Default = Auto)
Min/Max = 0.0 s ... 5.0 s, 0.1 s step (Default =
0.0 s)
Min/Max = 0.0 s ... 15.0 s, 0.1 s step (Default
= 0.1 s)
Min/Max = 0.0 s ... 30.0 s, Auto, 0.1 s step
(Default = Auto)
Value
Min/Max = 0.0 s ... 9.9 s, Auto, 0.1 s step
(Default = Auto)
Min/Max = 0.0 s ... 30.0 s, Auto, 0.1 s step
(Default = Auto)
Value
-60 % ... 0 % (Default = -25%)
30 Hz ... 250 Hz (Default = 60 Hz)
Value
2 A ... Power source max A, 1 A step *
10 % ... 70 %, 1 % step (Default = 40 %) *
10 % ... 70 %, 1 % step (Default = 20 %), amperes vis-
ible *
(DC): 0.2 Hz ... 300 Hz, 1 Hz step (0.2 Hz ... 10 Hz step is
0.1 Hz) (Default = 1 Hz) *
(AC): 0.2 Hz ... 20 Hz, 1 Hz step (0.2 Hz ... 10 Hz step is
0.1 Hz) (Default = 1 Hz) *
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
This adjustment is not available when Hot start is
off.
Hot start time cannot be adjusted when 4T trigger
logic is selected.
This adjustment is not available when the 2T trig-
ger logic is selected.
Note
This adjustment is not available when the Lift TIG igni-
tion is turned on.
Note
This adjustment is not available when the Lift TIG igni-
tion is turned on.
Note
Note
31
Operating manual - EN
1920900 / 2052