Current Mode View - Kemppi MasterTig 235ACDC Operating Manual

Hide thumbs Also See for MasterTig 235ACDC:
Table of Contents

Advertisement

"Welding processes and features" on page 72

3.3.6 Current mode view

To adjust parameters:
1.
Go to the Current mode view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter to be adjusted by pressing the control knob (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob (1).
Adjustable parameters:
Parameter
Current mode
AC Waveform
AC Frequency
AC+ / AC- balance
MIX TIG AC (time) ratio
MIX TIG cycle time
MIX TIG DC level
"Welding processes and features" on page 72
© Kemppi
Value
DC- / DC+ / AC / MIX
Sine / Optima / Square (Default: Optima)
30 Hz ... 250 Hz (Default = 60 Hz)
Min/Max = -60 % ... 0 % (Default = -25%)
Min/Max = 10 % ... 90 %, step 1 % (Default = 50 %)
Min/Max = 0.1 s ... 1.0 s, step 0.1 s (Default = 0.6 s)
Min/Max = 50 % ... 150 %, step 1 % (Default = 100 %)
45
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Operating manual - EN
1920900 / 2052

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mastertig 325dcMastertig 335acdcMastertig 425dcMastertig cooler mMastertig 235acdc gmMastertig 325dc g ... Show all

Table of Contents