Downslope
Tail arc
Post gas
Adjustable parameters in spot welding:
Parameter
Pre gas
Upslope
Spot time
Downslope
Post gas
Adjustable parameters in MicroTack welding:
Parameter
Pre gas
MicroTack spot time
MicroTack pause time
MicroTack spot count
Post gas
"Welding processes and features" on page 72
© Kemppi
OFF / 0.1 s ... 15.0 s (Default = 0.1 s)
OFF / 5 % ... 90 % (Default = OFF)
0.1 s ... 30.0 s / AUTO, 0.1 s step
Value
0.0 s ... 10.0 s, Auto, 0.1 s step (Default =
Auto)
OFF / 0.1 s ... 5.0 s, 0.1 s step (Default = 0.0 s)
0.0 s ... 10.0 s, step 0.1 s (Default = 2.0 s)
OFF / 0.1 s ... 15.0 s (Default = 0.1 s)
0.1 s ... 30.0 s / AUTO, 0.1 s step (Default =
Auto)
Value
0.0 s ... 10.0 s, Auto, 0.1 s step (Default =
Auto)
1 ms ... 200 ms, step 1 ms (Default = 10 ms)
50 ms ... 500 ms, step 1 ms (Default = 50
ms)
1 ... 5 / endless, step 1 (Default = 1)
0.1 s ... 30.0 s / AUTO, 0.1 s step (Default =
Auto)
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Note
Note
This is not visible in the settings if the MicroTack pulse
count is only 1.
If Lift TIG is used, MicroTack graph shows only 1 spot
and the spot count parameter is not visible.