Kemppi MasterTig 235ACDC Operating Manual page 34

Hide thumbs Also See for MasterTig 235ACDC:
Table of Contents

Advertisement

Balance min
Balance max
Lift TIG current
Cooler flow watch
Positive ignition current
Negative ignition current
Ignition current
Positive ignition time
Negative ignition time
Ignition time
Slight upslope
Startup level
Downslope cut level
2T downslope cut
Nonlinear downslope
Current freezing
AC phase swap current
Info
Software version
Factory reset
* Current range adjustable by welder in TIG welding:
2 A ... 130 A, 1 A step (MasterTig 235, limited supply mode)
2 A ... 235 A, 1 A step (MasterTig 235)
2 A ... 305 A, 1 A step (MasterTig 325, 335)
2 A ... 405 A, 1 A step (MasterTig 425)
Default = 3 A ... Nominal value of the power source.
* Current range adjustable by welder in MMA welding:
8 A ... 85 A, 1 A step (MasterTig 235, limited supply mode)
8 A ... 185 A, 1 A step (MasterTig 235)
8 A ... 255 A, 1 A step (MasterTig 325, 335)
8 A ... 355 A, 1 A step (MasterTig 425)
Default = 10 A ... MMA maximum current of the power source.
"Welding processes and features" on page 72
© Kemppi
-99 % ... 0 % (Default = -60 %)
0 % ... 20 % (Default = 0 %)
5 A ... 40 A / Auto (Default = Auto)
OFF / ON (Default = ON)
30 % ... 150 % / Auto, step 1 % (Default =
Auto)
(AC/DC): 100 % ... 300 % / Auto, Step 1 %
(Default = Auto)
(DC): 100 % ... 300 % / Auto, step 1 %
(Default = Auto)
0 ms ... 50 ms / Auto, step 10 ms (Default =
Auto)
(AC/DC): 0 ms ... 950 ms / Auto, step 10 ms
(Default = Auto)
(DC): 0 ms ... 950 ms / Auto, step 10 ms
(Default = Auto)
OFF / ON (Default = OFF)
5 % ... 40 %, step 1 % (Default = 10 %)
5 % ... 40 %, step 1 % (Default = 10 %)
OFF / ON (Default = OFF)
0 % ... 50 %, step 1 % (Default = 0 %)
OFF / ON (Default = OFF)
5 A ... 20 A / Auto
Machine type, serial number
Power source and control panel software
version number
Cancel / Reset (Default = Cancel)
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Resets to TIG, DC-, 50 A, HF, Pulse OFF (other values as
per default). Once the factory reset is complete, the
power source must be restarted manually.