MIX TIG AC ratio
MIX TIG cycle time
MIX TIG DC level
MicroTack spot time
MicroTack pause time
MicroTack spot count
Arc force
Hot start
VRD
MMA Antifreeze
HF spark force
TIG antifreeze
Remote mode
Remote control min
Remote control max
Wireless remote
Water cooler
Weld data time
Display off
Date
Time
Language
Time counter
Time counter (since
date)
Reset counter
4T trigger logic
Advanced settings (hidden in standard view):
Parameter
Current limit min
Current limit max
© Kemppi
10 % ... 90 %, step 1 % (Default = 50 %)
0.1 s ... 1.0 s, step 0.1 s (Default = 0.6 s)
50 % ... 150 %, step 1 % (Default = 100 %)
1 ms ... 200 ms, step 1 ms (Default = 10 ms)
50 ms ... 500 ms, step 1 ms (Default = 50 ms)
1 ... 5, Endless (Default = 1)
-10 ... +10 , step 1 (Default = 0)
-10 ... +10 , step 1 (Default = 0)
OFF / ON (Default = OFF)
OFF / ON (Default = ON)
50 % ... 110 %, Step 1 % (Default 100 %)
OFF / ON (Default = OFF)
OFF / Remote / Torch (Default = OFF)
Min = "Current limit min", Max = "Current limit
max"
Min = "Current limit min", Max = "Current limit
max"
Cancel / Start (Start pairing)
OFF / Auto / ON (Default: Auto)
OFF / 1 s ... 10 s, step 1 s (Default = 5 s)
5 min ... 120 min, step 1 min (Default = 5 min)
Date setting (DD/MM/YYYY)
Time setting (HH:MM)
Select language from the list
Total arc time and power on time
Total arc time and power on time since last
reset
Time counter reset
4T MLOG / 4T LOG / 4T LOG+ (Default = 4T
MLOG)
Value
TIG: 2 A / MMA: 8 A, step 1 A *
TIG: power source's nominal value / MMA:
power source's max. MMA current, step 1 A
*
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
In AU VRD (Voltage Reduction Device) version:
Default ON, OFF disabled.
Set the day by pressing and turning the control knob.
Once the day is set, press the control knob button to
set the month etc.
Set the hour by pressing and turning the control
knob (use 24 h format). Once the hour is set, press
the control knob button to set the minutes.