The AC/DC function (4) is not available with the MTP23X control panel.
To select and adjust Start & stop parameters:
1.
Press the Start & stop button (9) to enter the parameter settings.
2.
Browse through the curve / menu parameters by turning the control knob (1).
3.
Select the parameter for adjusting by pressing the control knob button (1).
4.
Adjust the selected parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob again (1).
To select and adjust AC and/or Pulse parameters:
1.
Press the Current mode selection button (4) to switch to AC mode.
2.
Press the Pulse mode selection button (7) to switch between Pulse modes.
3.
Press the Start & stop button (9) to enter the parameter settings.
4.
Browse to the AC or Pulse settings in the parameter menu by turning the control knob (1).
5.
Select the AC or Pulse parameter for adjustment by pressing the control knob button (1).
6.
Adjust the selected parameter's value by turning the control knob (1).
7.
Close the parameter setting by pressing the control knob button (1).
The Current mode and Pulse mode selections have an effect on the Start & stop menu contents.
Adjustable parameters in continuous welding:
Parameter
Pre gas
Upslope
© Kemppi
Value
Min/Max = 0.0 s ... 9.9 s, Auto, 0.1 s step (Default =
Auto)
Min/Max = 0.0 s ... 5.0 s, 0.1 s step (Default = 0.0 s)
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Note
This adjustment is not available when the Lift TIG
ignition is turned on.