Fire Alarm Macro; Christie Act Actions - Christie CP4315-RGB User Manual

Cinema 4k-rgb
Hide thumbs Also See for CP4315-RGB:
Table of Contents

Advertisement

Action Item
Available Actions
Disable Subtitle
Jog
Projector
Douser Open
Douser Close
Light On
Light Off
Standby
Channel
Revert Warp File
Full Power
Wait

Fire alarm macro

By default, the projector is configured with a macro that uses a building fire alarm as the trigger.
If the projector is connected to the building's fire alarm system (recommended installation), the
default FIRE_ALARM macro performs the following actions in sequence:
1. Stops the playback of content.
2. Puts the projector into Standby mode.
You can also create a custom macro that uses the fire alarm trigger or edit the default fire alarm
macro to perform other actions as needed.
Related information
Adding an action item to an existing macro (on page 86)
Creating a macro (on page 85)

Christie ACT actions

These are the available built-in commands for the Christie ACT:
Command
Description
Buzzer
Activates the buzzer for the specified time (in milliseconds)
Button
Simulates pressing or holding the ACT button
Pulse Relay
Sends a pulse to a specific relay
Open Relay
Opens a specific relay
Close Relay
Closes a specific relay
Pulse GPO
Sends a pulse to a specific GPO pin
Cinema 4K-RGB User Guide–CP4315-RGB, CP4320-RGB, CP4325-RGB, CP4330-RGB
020-102712-06 Rev. 1 (03-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
Description
Disables subtitles for the current content and onward
Moves content forward by the time specified
Opens the douser (shutter)
Closes the douser (shutter)
Turns the light on
Turns the light off
Puts the projector in standby mode
Selects a specific projector channel
Reverts the active warp file to its previous settings
Places the projector in full power mode
Delays the execution of a macro