Fire Alarm Macro; Christie Act Actions - Christie CineLife+ CP4415-RGB User Manual

Hide thumbs Also See for CineLife+ CP4415-RGB:
Table of Contents

Advertisement

Action Item
Available Actions
Light On
Light Off
Standby
Channel
Revert Warp File
Full Power
Wait

Fire alarm macro

By default, the projector is configured with a macro that uses a building fire alarm as the trigger.
If the projector is connected the building's fire alarm system (recommended installation), the default
FIRE_ALARM macro puts the projector into Standby mode if a fire alarm occurs.
You can also create a custom macro that uses the fire alarm trigger or edit the default fire alarm
macro to perform other actions as needed.

Christie ACT actions

These are the available built-in commands for the Christie ACT:
Command
Description
Buzzer
Activates the buzzer for the specified time (in milliseconds)
Button
Simulates pressing or holding the ACT button
Pulse Relay
Sends a pulse to a specific relay
Open Relay
Opens a specific relay
Close Relay
Closes a specific relay
Pulse GPO
Sends a pulse to a specific GPO pin
Set All GPOs
Sets the values for all GPO pins
Run Script
Runs a script on the Christie ACT
Flash LED
Causes a specific LED to flash
Set All LEDs
Sets values for all of the LEDs
CineLife+ User Guide–CP4415-RGB, CP4420-RGB, CP4440-RGB, CP4450-RGB
020-103073-03 Rev. 1 (01-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
Description
Turns the light on
Turns the light off
Puts the projector in standby mode
Selects a specific projector channel
Reverts the active warp file to its previous settings
Places the projector in full power mode
Delays the execution of a macro
Automation