Crestron CHV-THSTAT Operation And Installation Manual page 88

Heating/cooling and humidity thermostat
Hide thumbs Also See for CHV-THSTAT:
Table of Contents

Advertisement

Thermostats
ID Strings Description
FUNCTION
System Type
System Type Suffix
Heat Stages
Cool Stages
Heat Anticipator
Cool Anticipator
Slab Temperature Max
Regulation Index
Interstage Differential
Heat Pump Balance Point
Aux Balance Point
Offset Temperature
Auto Deadband
Temperature Unit
Sensor Usage Flags
82 • Thermostats: CHV-TSTAT and CHV-THSTAT
OPTIONS
DESCRIPTION
H/C, HP, SB1,
Heat/cool, heat pump, or slab system
SB2, SB3,
SB4A, SB4B,
SB5A, SB5B
RD
Radiant
FA
Forced Air
DF
Heat pump with Dual Fuel
AX
Heat pump with Auxiliary
H1, H2
Number of heating stages, 1 or 2
C1, C2
Number of cooling stages, 1 or 2
HA1 - HA6
Heat anticipator setting, from 1-6
CA1 - CA6
Cooling anticipator setting, from 1 - 6
SMX
Maximum slab temperature for Slab2, Slab3, Slab4A ,and Slab4B types
followed by a number (example: SMX100)
SRG
Floor warming regulation index for Slab1, Slab3, Slab5A, and Slab5B
types followed by a number (example: SRG4)
ID
Differential for multistage heat/cool, heat pump, Slab4A, and Slab4B
types followed by a number (example: ID1.0)
HBP
Balance point for heat pump, Slab4B, and Slab 5B types followed by a
number (example: HBP-10)
ABP
Balance point for heatpump, Slab4B, and Slab5B types followed by a
number (example: ABP70)
OS
Offset temperature display value, followed by a number from -6 to 6
degrees (Example: OS-1)
ADB
Minimum separation between heat and cool setpoints in auto mode,
degrees, 2 – 6, for systems containing cooling only (Example: ADB3)
F
Fahrenheit
C10
Celsius whole units
C05
Celsius half units
U, D, O
Indicates the status of each sensor input: Use, outDoor, or Omit, sensor
series is as follows:
Built-in-temp; built-humidity; remote 1 temp; remote1 hum; remote 2
temp; remote 2 hum.
NOTE: Depending on system type, not all of the ID String options listed above will
be present.
NOTE: If you are in setup, the word SETUP appears in the string after the list of
sensors.
NOTE: If you have restored a version 1.0 or 1.1 setup in this power cycle, an R
appears after the word SETUP.
Crestron CHV-TSTAT and CHV-THSTAT
Operations and Installation Guide – DOC. 8163C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chv-tstat

Table of Contents