CHV-TSTAT-FCU-PIR-10 Supplemental Guide Crestron Electronics, Inc.
Page 2
Certain Crestron products contain open source software. For specific information, visit www.crestron.com/opensource. Crestron and the Crestron logo are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
Page 3
Contents Introduction Set Up the Thermostat Enter Setup Mode Navigate Setup Mode Configure the Thermostat Supplemental Guide — 7964B Contents • i...
Page 4
ii • Contents Supplemental Guide — 7964B...
Page 5
Introduction After installation, the Crestron® CHV-TSTAT-FCU-PIR-10 needs to be set up. Refer to the information that follows for an overview of the setup procedure. For more installation information on the CHV-TSTAT-FCU-PIR-10, refer to the CHV-TSTAT-FCU-PIR-10 Quick Start Guide (Doc. 7915) at crestron.com/manuals.
Page 6
Up (p) and Down (q) buttons to change the value for the selected item. Configure the Thermostat SETUP: SYSTEM Screen Use the Heat Type option to select the type of HVAC system that the thermostat is controlling. 2 • CHV-TSTAT-FCU-PIR-10 Supplemental Guide — 7964B...
Page 7
BOOKED TIMEOUT should be used in a room that is occupied regularly, such as in a booked hotel room. BOOKED TIMEOUT should be set for a longer period of time than UNBOOKED TIMEOUT to ensure that the room does not enter the vacancy state while regularly occupied. Supplemental Guide — 7964B CHV-TSTAT-FCU-PIR-10 • 3...
Page 8
The Heat, Cool, and Fan calls are settable via 0.1 V increments. When the device operates as a relay, Heat Call is relegated to ON or OFF. The PIR displays DETECTED when motion is detected. 4 • CHV-TSTAT-FCU-PIR-10 Supplemental Guide — 7964B...
Page 9
Set the Display Temp to N to only display the setpoint temperature on the front panel of the device. SETUP: FAN VOLTAGE Screen Use the SETUP: FAN VOLTAGE screen to select the voltages corresponding to the high, medium, and low fan speeds. Supplemental Guide — 7964B CHV-TSTAT-FCU-PIR-10 • 5...
Page 10
This page is intentionally left blank. Supplemental Guide — 7964B CHV-TSTAT-FCU-PIR-10 • 6...