Thermostats
Slot 2 – Humidity Control (continued)
SIGNAL
Remote2Humidity
OutdoorHumidity
Slot 3 Detail View – Slab Control
68 • Thermostats: CHV-TSTAT and CHV-THSTAT
I/O
SIGNAL
DEFINITION
TYPE
Output
Analog
Reports the humidity reading of the Remote 2 humidity sensor in
whole numbers.
The Remote 2 humidity sensor reading is reported regardless of
the Use/Omit/OD designation.
Output
Analog
Reports the humidity reading of any humidity sensor set to "OD"
(Outdoor) in whole numbers.
If more than one humidity sensor is set to OD, this is the mean
outdoor humidity.
Humidity sensors are manually set to Use, Omit, or Outdoor via
the setup menus on the thermostat.
Crestron CHV-TSTAT and CHV-THSTAT
Operations and Installation Guide – DOC. 8163C