  • Page 1 CHV-TSTAT-FCU-PIR-10 Heating and Cooling Fan-Coil Thermostat Supplemental Guide Crestron Electronics, Inc.
  • Page 2 Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.
  • Page 3 Contents Introduction Set Up the Thermostat Enter Setup Mode ....................1 Navigate Setup Mode ..................... 1 Configure the Thermostat..................2 Supplemental Guide – DOC. 7964A Contents • i...
  • Page 5 CHV-TSTAT-FCU-PIR-10: Heating and Cooling Fan-Coil Thermostat Introduction After installation, the Crestron CHV-TSTAT-FCU-PIR-10 needs to be set up. Refer to the ® information that follows for an overview of the setup procedure. For more information on the CHV-TSTAT-FCU-PIR-10, refer to the CHV-TSTAT-FCU-PIR-10 DO Guide (Doc.
  • Page 6: Configure The Thermostat

    The BOOKED TIMEOUT determines how long the room must be empty, as determined by the PIR, before the room enters the vacant state. Vacancy state is defined in the control system program. 2 • CHV-TSTAT-FCU-PIR-10: Heating and Cooling Fan-Coil Thermostat Supplemental Guide – DOC. 7964A...
  • Page 7 The PIR displays DETECTED when motion is detected. SETUP: DISP OPTIONS Screen The SETUP: DISP OPTIONS screen allows adjusting of both the displayed and the regulated temperatures. Supplemental Guide – DOC. 7964A CHV-TSTAT-FCU-PIR-10: Heating and Cooling Fan-Coil Thermostat • 3...
  • Page 8 SETUP: FAN VOLTAGE Screen Use the SETUP: FAN VOLTAGE screen to select the voltages corresponding to the high, medium, and low fan speeds. 4 • CHV-TSTAT-FCU-PIR-10: Heating and Cooling Fan-Coil Thermostat Supplemental Guide – DOC. 7964A...
  • Page 9 This page is intentionally left blank. Supplemental Guide – DOC. 7964A CHV-TSTAT-FCU-PIR-10: Heating and Cooling Fan-Coil Thermostat • 5...
  • Page 10 Crestron Electronics, Inc. Supplemental Guide – DOC. 7964A 15 Volvo Drive Rockleigh, NJ 07647 (2048038) Tel: 888.CRESTRON 01.17 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.