Operating The Thermostat - Crestron CHV-THSTAT Operation And Installation Manual

Heating/cooling and humidity thermostat
Hide thumbs Also See for CHV-THSTAT:
Table of Contents

Advertisement

Crestron CHV-TSTAT and CHV-THSTAT

Operating the Thermostat

Main Screen
66
o
68
F
o
F
MODE
HEATING
HEAT ONLY
%
43
ON LINE
VIEW
H1
This example shows:
• The current temperature as 66
• The current humidity as 43%
• The Heating Setpoint as 68
• The heating system is running
• The thermostat is on-line
• System mode is HEAT ONLY
System Mode Screen
System Mode
MODE
HEAT COOL AUTO OFF
VIEW
AUX HEAT ONLY
Operations and Installation Guide – DOC. 8163C
After setup, configure the thermostat using the following screens.
The Main Screen displays the Current Temperature, System Mode, Fan
Mode, and Set Point temperatures. The CHV-THSTAT also displays
Relative Humidity. Press the up ▲arrow button to increase the set point
temperature. Press the down ▼arrow button to decrease the set point
temperature.
NOTE: If you selected Yes in setup screen Display Options for "Dual
Setpoint Auto", pressing MODE toggles between the Heat and Cool
setpoints while they are flashing. Pressing Mode will not change the screen
o
F
until the setpoint has stopped flashing.
This screen also indicates the system currently running:
o
F
H1 – Heat System or Stage 1 Heat System
H2 – Stage 2 Heat System
AX – Auxiliary Heating System
C1 – Cooling System or Stage 1 Cooling System
C2 – Stage 2 Cooling System
SB – Slab heat system
HM– Humidifier
NOTE: System indicators flash to indicate short cycle timer protection (timer
guards) engaged.
MODE Button
MODE
It may also be necessary to access the following series of screens. Pressing
the MODE button allows the user to access the following screens:
1. System Mode screen and/or Slab System Mode screen(s)
2. Fan Mode screen
3. Humidifier screen
4. Crestron System screen
5. Global Update screen
1. System Mode or Slab System Mode
The "System Mode" screen appears when the MODE button is initially
pressed. Use the up ▲and down ▼arrow buttons to select HEAT, COOL,
AUTO, OFF or AUX HEAT ONLY.
If your system is SLAB 1, SLAB 3, or SLAB 5, the Slab System Mode
screens appear as described on the following page.
NOTE: The AUTO selection allows the system to switch between Heat and
Cool automatically as needed to maintain the temperature.
NOTE: The AUX HEAT ONLY is for the backup heating system on Heat
Pump based systems only. It allows the backup system to operate without
operating the heat pump.
Thermostats: CHV-TSTAT and CHV-THSTAT • 55
Thermostats

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chv-tstat

Table of Contents