CONNeCTION Of THe POWer UNIT
4.2.5.7 Terminal block X1B motor connection
X1b
Figure 13:
Terminal block X1B motor connection
4.2.5.8 Wiring of the motor
Legend
1 KEB COMBIVERT
2
3 Three-phase motor
4
5 Connection via shield plate (if not available, place on mounting plate)
Figure 14:
NOTICE
40
Name
function
Motor connec-
U, V, W
tion
Connection for
PE,
protective earth
T1 T2
L1
L2
L3
Apply motor cable, shielding on both sides over a large surface on the motor
housing
Temperature monitoring (optional)
=>
„4.2.7 Connection of a temperature detection"
Wiring of the motor
ensure correct laying of the PTC cables !
•
Do not lay PTC cable of the motor (also shielded) together with con-
trol cable !
•
PTC cable inside the motor cable only permissible with an addition-
ally shielding (double shielding) !
Cross-section
AWG without
mm² with
wire-end
wire-end
ferrule
ferrule
20...8
2.5...10
stranded wire
Screw M4
for ring crimp connector
U
U
V
V
W
W
➄
Tightening
torque
1.2...1.5 Nm
12 lb-inch
1.3 Nm
11 lb inch
➃