Use Of Non-Intrinsically Safe Braking Resistors - KEB COMBIVERT G6 Instructions For Use Manual

Hide thumbs Also See for COMBIVERT G6:
Table of Contents

Advertisement

CONNeCTION Of THe POWer UNIT

4.2.6.3 Use of non-intrinsically safe braking resistors

WArNING
42
Use of non-intrinsically safe braking resistors
fire or smoke development in case of overload or fault !
► Only use braking resistors with temperature sensor.
► Evaluate temperature sensor.
► Trigger fault on the drive controller (e.g. external input).
► Switch off input voltage (e.g. input contactor).
► Connection examples for non-intrinsically safe braking resistors
=>
Instructions for use „Installation Braking Resistors".
Instructions for use „Installation Braking Resistors"
www.keb.de/fileadmin/media/Manuals/dr/ma_dr_braking-resis-
tors-20116737_en.pdf