SA 07.2-UW
SA 16.2-UW / SAR 07.2-UW
AC 01.2 Non-Intrusive Profinet

4.2.1.1. Multi-turn actuator with output drive type B: mount

Procedure
SAR 16.2-UW Control unit: electronic (MWG)
Figure 9: Mounting output drive types B
[1]
Multi-turn actuator
[2]
Valve/gearbox
[3]
Valve/gearbox shaft
1.
Check if mounting flanges fit together.
2.
Check if output drive of multi-turn actuator [1] matches the output drive of
valve/gearbox or valve/gearbox valve shaft [2/3].
3.
Apply a small quantity of grease to the valve or gearbox shaft [3].
4.
Place multi-turn actuator [1] and ensure that the spigot fits uniformly in the recess
and that the mounting faces are in complete contact.
5.
Fasten multi-turn actuator with screws according to table.
Information: We recommend applying liquid thread sealing material to the
screws to avoid contact corrosion.
6.
Fasten screws crosswise to a torque according to table.
Table 4:
Tightening torques for screws
Threads
M6
M8
M10
M12
M16
M20
Tightening torque [Nm]
Strength class A2-80/A4 80
10
24
48
82
200
392