SECTION 4 - MACHINE OPERATION

ZIVAN High Frequency Electronic Charger

Charging the battery :
- Plug the charger into the mains (single phase 230
VAC 2 poles + ground).
- The charger starts automatically.
Charging phase indicator on
the charger :
Red LED : The charger is in
the charge initial phase
(phase 1).
Flashing Red LED : The
charger is in a constant
tension phase (phase 2).
Yellow LED : The battery is
80% charged.
Green LED : The battery is
100% charged.
Alarms :
A flashing LED and an intermittent acoustic alarm
indicate a faulty situation. When the alarm is on, the
charger no longer delivers any current.
Leds signal :
ALARM
CONDITION
TYPE
Batteries
RED
presence
GREEN
Timeout
RED /
Battery
YELLOW
current
RED /
Battery
GREEN
voltage
YELLOW /
Selection
GREEN
RED /
Thermal
YELLOW /
safety
GREEN
4-6
DESCRIPTION (Action)
Battery disconnected or not in
conformity.
(Verify the connection and the
nominal voltage).
Phase 1 and/or Phase 2 have a
duration in excess of the maximal
allowed.
(Verify the battery capacity).
Loss of output Current control.
(Failure of the control logic).
Loss of output Voltage control.
(Battey disconnected or failure of
the control logic).
An unavailable configuration has
been selected.
(Verify the selector's position).
Overheating of semiconductors.
(Check for proper operation of the
fan).