11. OPERATING LOGICS TABLE

Tab. 1/a
LOGIC "A"
AUTOMATED
SYSTEM STATUS
opens and closes
CLOSED
after the pause
WHEN OPENING
OPEN IN PAUSE
pause time
immediately
WHEN CLOSING
reverses to
BLOCKED
Tab. 1/b
LOGIC "A1"
AUTOMATED
SYSTEM STATUS
opens and closes
CLOSED
after the pause
WHEN OPENING
OPEN IN PAUSE
pause time
immediately
WHEN CLOSING
reverses to
BLOCKED
Tab. 1/c
LOGIC "E"
AUTOMATED
SYSTEM STATUS
CLOSED
WHEN OPENING
operation
OPEN
immediately
WHEN CLOSING
reverses to
BLOCKED
 In brackets, the effects on the other inputs when the pulse is active
OPEN A
CLOSE
no effect
time
immediately
no effect
reverses to
closing
resets
closes
no effect
opening
closes
closes
OPEN A
CLOSE
no effect
time
immediately
no effect
reverses to
closing
resets
closes
no effect
opening
closes
closes
OPEN A
CLOSE
opens
no effect
immediately
blocks
reverses to
closing
closes
closes
no effect
opening
closes
closes
PULSES
STOP
FSW
no effect
no effect
(opening inhibited)
blocks
no effect
operation
resets pause
blocks
time
operation
(closing inhibited)
immediately
blocks
reverses to
operation
opening
no effect
no effect
(opening and
(closing inhibited)
closing inhibited)
PULSES
STOP
FSW
no effect
no effect
(opening inhibited)
closes
blocks
immediately
after opening is
operation
completed
blocks
closes
operation
immediately
blocks
reverses to
operation
opening
no effect
(opening and
inhibits closing
closing inhibited)
PULSES
STOP
FSW
no effect
no effect
(opening inhibited)
blocks
no effect
operation
no effect
no effect
(closing inhibited)
(closing inhibited)
immediately
blocks
reverses to
operation
opening
no effect
no effect
(opening and
(closing inhibited)
closing inhibited)
33
LOOP 1
LOOP 2
opens and closes
after the pause
no effect
time
no effect
no effect
resets pause
resets
time
pause time
(closing inhibited)
immediately
immediately
reverses to
reverses to
opening
opening
opens and closes
no effect
after the pause
(closing inhibited)
time
LOOP 1
LOOP 2
opens and closes
after the pause
no effect
time
closes
immediately
no effect
after opening is
completed
resets
closes when
pause time
disengaged
immediately
immediately
reverses to
reverses to
opening, closes
opening, closes at
again once opening
the end of pause
is completed
opens and closes
no effect
after the pause
(closing
time
inhibited)
LOOP 1
LOOP 2
opens
no effect
no effect
no effect
no effect
no effect
(closing inhibited)
immediately
immediately
reverses to
reverses to
opening
opening
no effect
opens
(closing inhibited)

Hide quick links: