Operating Logics - FAAC E045S User Manual

Table of Contents

Advertisement

Function
rB
SEARCH FOR STOP
En
(displayed only if
This function specifies the angular space in which
to search for the opening/closing stop. In this
space, the automation is stopped by a mechanical
stop/obstacle and not by the anti-crushing system.
00
~1°
02
~4°
S p
PROGRAMMING OUTPUT W.L.
00
LED function
06
automation closed warning
tA
ADDITIONAL OPERATING TIME
En
(displayed only if
Adds additional operating time at the end of the
movement.
00
30
...
(Adjustment step: 1 s)
S t
LEAVING THE PROGRAMMING MODE
Y
exit saving the settings
no
exit without saving the settings
After having confirmed using button
indicates the STATUS of the automation:
00
CLOSED
01
OPEN
02
STATIONARY THEN OPENS
03
STATIONARY THEN CLOSES
04
IN PAUSE
05
OPENING
E045S
default
02
Y
=
)
00
03
no
=
)
F F
, the display
06
CLOSING
07
FAILSAFE IN PROGRESS
08
CHECK Bus 2easy
09
P R E F L A S H I N G B E F O R E
OPENING
10
P R E F L A S H I N G B E F O R E
CLOSING

6.3 OPERATING LOGICS

i
the STOP command has priority in all the logics and
stops the automation.
The CLOSE command always closes the automation.
E
SEMI-AUTOMATIC
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening, stops the gate and the next
OPEN command closes it.
OPEN during closing, causes it to reopen.
The triggering of the photocells: during movement,
reverses the gate.
EP
SEMI-AUTOMATIC STEP-BY-STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
Y
OPEN if the automation is open, causes it to close.
OPEN during opening or closing, stops the gate and
the next OPEN command reverses the direction.
The triggering of the photocells: during movement,
reverses the gate.
SP
AUTOMATIC STEP BY STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during pause, causes it to close.
OPEN during opening or closing, stops it and the
next OPEN command reverses the direction.
The triggering of the closing photocells: during
pause, closes the gate - during opening, requests
closing - during closing, causes the gate to open and
then closes it immediately.
A
AUTOMATIC
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during the pause, resets the pause time.
OPEN during opening, is ignored.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during pause,
reloads the pause time.
14
532373 - Rev.A

Advertisement

Table of Contents
loading

Table of Contents