2.5.4

OPERATING LOGICS

GATE STATUS
Closed
Opens leaves and re-
closes after pause time
Open in pause
Closes at once
Closing
Reverses gate movement
Opening
GATE STATUS
Closed
Opens leaves and re-
closes after pause time
Open in pause
Closes at once
Closing
Stops gate motion and,
at next pulse, opens
Opening
Stops gate motion and,
at next pulse, closes
GATE STATUS
Closed
Opens leaves
Open
Closes at once
Closing
Reverses gate movement
Opening
Reverses gate movement
SEMIAUTOMATIC STEP-BY-STEP LOGIC (DIP-SWITCH 2=OFF / DIP-SWITCH 3=ON
GATE STATUS
Closed
Opens leaves
Open
Closes at once
Closing
Stops gate movement
and, at next pulse, opens
Opening
Stops gate movement
and, at next pulse,
(1)
The operation described in the tables is obtained if the STOP input is enabled (dip-switch 6 = OFF).
When the input is disabled, the command has no effect.
(2)
The operation described in the tables is obtained if the input of the photocells is enabled (dip-switch 7
= OFF). When the input is disabled, the command has no effect.
(3)
In single motor installations, partial opening of the gate corresponds to about 60% of the memory
stored opening. In two-motor installations, partial opening corresponds to the total opening of the leaf
on which motor M1 is installed.
AUTOMATIC LOGIC (DIP-SWITCH 2=ON / DIP-SWITCH 3=OFF
OPEN A
Partially opens the gate
Closes at once
No effect
STEP-BY-STEP AUTOMATIC LOGIC (DIP-SWITCH 2=ON / DIP-SWITCH 3=ON
OPEN A
Partially opens the gate
Closes at once
SEMIAUTOMATIC LOGIC (DIP-SWITCH 2=OFF / DIP-SWITCH 3=OFF
OPEN A
Partially opens the gate
Closes at once
OPEN A
Partially opens the gate
Closes at once
closes
PULSES
OPEN B
(3)
Disables OPEN commands
Stops pause time count
No effect
Stops operation
No effect
Stops operation
PULSES
OPEN B
(3)
Disables OPEN commands
Stops pause time count
No effect
Stops operation
No effect
Stops operation
PULSES
OPEN B
(3)
Disables OPEN commands
Stops operation
No effect
Stops operation
No effect
Stops operation
PULSES
OPEN B
(3)
Disables OPEN commands
Stops operation
No effect
Stops operation
No effect
Stops operation
Rev. 01.2006 - Istallation Manual
(1)
STOP
Stops operation and on
release, if pause time
exceeded, closes after 5
Reverses motion
(1)
STOP
Stops operation and on
release, if pause time
exceeded, closes after 5
Reverses motion
STOP
(1)
On release, closes after 5
Reverses motion
(1)
STOP
On release, closes after 5
Reverses motion
Page 14
(2)
PHOTOCELLS
No effect
sec
No effect
(2)
PHOTOCELLS
No effect
sec.
No effect
PHOTOCELLS
(2)
No effect
sec.
No effect
(2)
PHOTOCELLS
No effect
sec.
No effect

Advertisement