Reader
W0
W1
IN,
LED OUT
Control
+U IN
Panel
W0
OUT,
2
LED IN (negated)
LED IN
 
G
 
TAMPER
2N TELEKOMUNIKACE a.s., www.2n.cz
GND
Isolated 2-wire WIEGAND IN
IN,
1
Isolated open LED OUT switched against GND (up to 24
V / 50 mA)
+U input (5 to 15 V DC) for WIEGAND OUT power supply
W1
GND
Isolated 2-wire WIEGAND OUT
OUT,
Isolated input for open LED IN, input activated by GND
connection
Isolated input for open LED IN, input activated by +U
connection
+U
WIEGAND OUT active supply LED indicator
IN
Tamper switch (Part No.
1
9155038
) input
2
73/105