What is Probe Plu
• The Probe Plus™ cooks by maintaining a constant temperature differential between the foods
internal temperature and the temperature in the cooking cavity of the oven.
• As the probe senses the internal product temperature increase, the Probe Plus™ raises the oven
cooking temperature.
• We don't set cooking time or cooking temperature; we simply set the Probe Plus™ differential
and the target internal temperature. The Line Chef™ Combination Oven does the rest.
• The Probe Plus™ feature will always be used with the probe.
• Probe Plus™ reduces shrinkage by cooking with lower and gentler heat.
Chef Loren....I still don't understand Probe Plus™.
• Place the probe in the thickest portion of the Prime Rib.
• Your raw beef roast has an internal temperature of 40ºF.; we set our Probe Plus™ differential at
100ºF. This means that the oven will begin cooking at a temperature of 140ºF. [100ºF + 40ºF =
140ºF roasting temperature].
• As the internal product temperature rises so does our oven temperature. When our beef reaches
an internal temperature of 80° the oven temperature has been raised, by Probe Plus™, to 180°F.
[100°F + 80°F = 180°F roasting temperature].
• When our beef is done, at an internal temperature of 130°F. our ovens highest roasting
temperature was 230°F. [130°F + 100°F. = 230°F.]
• Internal product temperature + temperature differential = Probe Plus™ cooking temperature.
To set the
[
∆T]
• Press the "Change Set Mode" touch pad to light the "Probe" icon.
• The control will read "PRB" in the "Time" window as you set the temperature.
• Set the probe to the desired finished product temperature.
• Place the probe in the thickest part of the product being cooked.
• Press the "Change Set Mode" touch pad to illuminate the "Set" light next to the "∆ºT" icon.
• Turn the temperature dial to show the desired Probe Plus™ differential temperature in the
temperature window.
• Press "Manual Start/Stop" to start cooking.
Venturi
• This is a patented system which speeds up the elimination of humidity in the cooking cavity.
• 100% Venturi can be used to reduce the oven temperature quickly when holding for
extended periods.
• Venturi is controlled with the dial in the "Climate" section of the control panel. The red lights
indicate the percent of dryness chosen [up to 100%].
• The Venturi controls the amount of dryness in the cooking chamber just as Combi controls the
amount of moisture in the cooking chamber.
• It is more difficult for products to brown in a moisture saturated environment than it is in a dry
environment.
• Venturi will be used to eliminate excess humidity when roasting large amounts of well done
products.