3.2.18 Error – temperature sensor Pt100 short – heating on the end sides
Status indication:
Yellow ERROR indicator is lit up continuously.
Operator's panel, Main Screen, 1st status line:
Operator's panel, Main Screen, 2nd status line:
Error Screen:
Status correction:
The error is possibly caused by disconnection of conductors 511, 512 or of the connector
connection of these conductors. See DA-41-400n, sheet 4. Repair.
A possible error of sensor Pt100 – ST2. Replace it.
Note:
At 80 °F (25 °C) it is possible to measure the resistance of this sensor of approximately 110Ω
for the orientation check of this sensor.
The error will reset as soon as temperature sensor ST2 shows the correct value. The error can
be suppressed by turning the heating off with the "HEATERS" rotary switch on the machine
control panel to STOP.
3.2.19 Status – the stacking unit attached to the machine is not running (it is stopped)
Note:
Applicable only in case a stacking unit is attached to the machine.
Status indication:
START button/indicator is blinking.
Yellow ERROR indicator is lit up continuously.
Operator's panel, Main Screen, 1st status line:
Operator's panel, Main Screen, 2nd status line:
Error Screen:
Status correction:
The attached stacking unit must be set into operation by pressing the "START" button before the
machine is started. Then the laminating machine can be started with the "START" button.