Service Manual – Electrical
3.2.3
Error – fuse FU11 is broken
Status indication:
Yellow ERROR indicator is lit up continuously.
Operator's panel, Main Screen, 1st status line:
Operator's panel, Main Screen, 2nd status line:
Error Screen:
Status correction:
Check fuse FU11 in the switchboard and if it is broken, replace it.
If the fuse is not broken, check the connection. See DA-41-100n. sheet 2
The electrical potential on conductor No. 217 at input PLC X35 must reach the voltage of 24 Vdc
(See DA-41-100n, sheet 7)
3.2.4
Error – space between sheets
Status indication:
START button/indicator is blinking.
Yellow ERROR indicator is blinking.
Operator's panel, Main Screen, 1st status line:
Operator's panel, Main Screen, 2nd status line:
Error Screen:
Status correction:
Check the space between the sheets.
Prevent sticking the foil to the pressure roll.
Quit the error by pressing buttons STOP, FEEDER UP, FEEDER DOWN
Start the machine by pressing button START.
3.2.5
Error - protection of the loading head
Status indication:
Yellow ERROR indicator is lit up continuously.
Operator's panel, Main Screen, 1st status line:
Operator's panel, Main Screen, 2nd status line:
Error Screen:
Status correction:
Check the position of the head and if it is deflected by the stack of paper sheets, loosen the
stack.
Move the loading table down and quit the error by pressing the "FEEDER DOWN" button
Check the connection on the branch of the loading head protective sensor (SQ6) according to
the wiring diagram (See DA-41-400n, sheet 5)
22
Fuse FU11 is broken
Space between sheets
Correct overlap of paper
Press button START or STOP
or Feeder UP or Feeder DOWN
Protection loading head
Press button Feeder DOWN
ERROR
Fuse FU11
or disconnected wire
Change fuse
or check wiring
ERROR
Missing sheets
ERROR
Protect. head
© 2004 General Binding Corporation