Operator Manual
4.2.5 Screen No. 2 Description
Display of actual
temperature - end
side of laminating roll
Snapper speed
display
Button to return to
Main Screen
Counting sheets mode on the laminating machine
1. Counting up
The machine adds every pulse of the snapping roll to the preset value. As soon as 99999 is reached,
the counter resets. If it is necessary to count from zero, set the counter value to 0.
2. Counting down
The machine deducts every pulse of the snapping roll from the preset value. As soon as 0 is reached,
the machine stops. The following message will be displayed on the operator's panel:
1st status line – Status,
2nd status line - Count finished.
The preset value will rewrite in the sheet counter. Start the laminating machine by pressing the
"START" button.
3. Counter reset
By the "RESET" button on the operator's panel.
Accelerating pulleys lift
If the accelerating pulleys are pushed down to a sheet of paper, lift them with the "ACEL.ROLL" button.
The laminating machine must be in the operational stop (i.e. the main motor is not turning). After
pressing the "ACEL.ROLL" button again, the accelerating pulleys are pushed down to the sheet of
paper.
28
Display of actual
temperature - middle of
laminating roll
Button to transfer to
Main Screen
© 2004 General Binding Corporation
Delta Laminator
Area to recall
numeric keyboard to
input preset value on
counter of sheets
Function switch –
counter up/down
Reset of counter of
sheets
Button to transfer to
Screen No. 3
Button for lifting
accelerating pulleys