Service Manual – Electrical
3.2.12 Error of the communication with frequency inverter U2
Status indication:
•
START button/indicator is blinking.
•
Yellow ERROR indicator is lit up continuously.
•
Operator's panel, Main Screen, 1st status line:
•
Operator's panel, Main Screen, 2nd status line:
•
Error Screen:
Status correction:
Note:
This error can be stopped with the "START" button/indicator. The machine will work without a problem
but the speed of the main motor will not be displayed.
•
Check if the conductors of the connecting cable between PLC, the machine control system and
frequency inverter U2 are not disconnected. See DA-41-100n, sheet 14. Repair. Switch the
machine off and on.
•
Defective communication module A7 PLC of the control system. Replace it.
•
Frequency inverter U2 is defective. Replace it.
3.2.13 Error – alarm of the heating regulator - in the middle
Status indication:
•
Yellow ERROR indicator is lit up continuously.
•
Operator's panel, Main Screen, 1st status line:
•
Operator's panel, Main Screen, 2nd status line:
•
Error Screen:
Status correction:
•
Check the value of the actual temperature of the laminating roll on the operator's panel. If it
exceeds the set acceptable limit 300 °F (150 °C), the most probable cause of the error is broken
solid state relay A2. See DA-41-100n, sheet 5. Replace it.
•
The error will reset as soon as the temperature of the laminating roll in its middle drops below
the set maximum acceptable limit 300 °F (150 °C).
26
Error communication with
frequency inverter U2
Check connection and
switch machine ON and OFF
Overheat lamination roller
- middle
ERROR
Communication U2
ERROR
Alarm middle