Service Manual – Electrical
3.2.12 Error of the communication with frequency inverter U2
Status indication:
START button/indicator is blinking.
Yellow ERROR indicator is lit up continuously.
Operator's panel, Main Screen, 1st status line:
Operator's panel, Main Screen, 2nd status line:
Error Screen:
Status correction:
Note:
This error can be stopped with the "START" button/indicator. The machine will work without a problem
but the speed of the main motor will not be displayed.
Check if the conductors of the connecting cable between PLC, the machine control system and
frequency inverter U2 are not disconnected. See DA-41-100n, sheet 14. Repair. Switch the
machine off and on.
Defective communication module A7 PLC of the control system. Replace it.
Frequency inverter U2 is defective. Replace it.
3.2.13 Error – alarm of the heating regulator - in the middle
Status indication:
Yellow ERROR indicator is lit up continuously.
Operator's panel, Main Screen, 1st status line:
Operator's panel, Main Screen, 2nd status line:
Error Screen:
Status correction:
Check the value of the actual temperature of the laminating roll on the operator's panel. If it
exceeds the set acceptable limit 300 °F (150 °C), the most probable cause of the error is broken
solid state relay A2. See DA-41-100n, sheet 5. Replace it.
The error will reset as soon as the temperature of the laminating roll in its middle drops below
the set maximum acceptable limit 300 °F (150 °C).
26
Error communication with
frequency inverter U2
Check connection and
switch machine ON and OFF
Overheat lamination roller
- middle
ERROR
Communication U2
ERROR
Alarm middle