Mounting Dimension Sheet Mbt530G / 530L - Bosch Rexroth IndraDyn T Project Planning Manual

Synchronous torque motors
Hide thumbs Also See for Rexroth IndraDyn T:
Table of Contents

Advertisement

Project Planning Manual | Rexroth IndraDyn T
14.6.2

Mounting Dimension Sheet MBT530G / 530L

Appendix to Motor Frame Size 530G/530L and 530 with Housing
The motor encoder is not in the scope of the motor delivery and
must be provided by the user.
The following steps must be done in general:
1.
Mount the motor encoder on the shaft.
2.
Close the motor housing and the encoder installation space with the pro‐
vided covers.
3.
Carry out the electric connection and the coolant connection according to
chapter 8 "Connection Techniques" on page
See
fig. 5-87 "Dimension sheet motor MBT530G, 530L - mounted rotor and
stator" on page
154.
Electric Drives
| Bosch Rexroth AG
and Controls
183.
255/261