363-208-010
Cabling, Wiring, and Assembly
These external cables must be engineered and fabricated for the complete
installation of the SLC -2000 RT Frame.
NOTE
All cables are not required for each installation. Refer to the regional equip-
ment engineering job specifications for a particular office application.
Some job specifications may order factory-assembled cables equipped with the
required connectors eliminating the need for installation fabrication at the job site.
Refer to the PARTS LISTS section to identify these assemblies by their connector
designations (J101, P205, etc.). These assemblies are installed by connecting
their connectors to their associated shelf mates. When these cables are not
provided in the job order, the installer must fabricate the customer's cables to the
appropriate connector according to the instructions provided in this and the
PARTS LISTS chapters.
Factory Cable Assembly Wire Color Coding Sequence
Standard wire color coding for the factory assembled cables is shown in the
following table. This coding sequence is followed on VF, DS1 and other cables
used as danglers and as Customer Interface connections. Use of the color coding
will facilitate both terminating operations at the customer's cross-connecting
points and troubleshooting routines.
Conductor
Pair No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
3-2
Issue 5 May 1997
:
Identification Colors (Tip/Ring)
white-blue/blue-white
white-orange/orange-white
white-green/green-white
white-brown/brown-white
white-slate/slate-white
red-blue/blue-red
red-orange/orange-red
red-green/green-red
red-brown/brown-red
red-slate/slate-red
black-blue/blue-black
black-orange/orange-black
black-green/green-black
black-brown/brown-black