363-208-010
Installation Procedures
ARM Shelf Installation
NOTE
Only one ARM shelf can be installed in the RT Bay. The shelf must be
located at the specific location depicted in the figure even if only one MDS
shelf is provided.
For ease of assembly the Power Interface Unit (PIU) should be mounted on
the ARM shelf before the shelf is mounted to its bay position.
404A User Interface Panel (UIP)
NOTE
This unit is considered a plug-in and shall be installed in accordance with
the instructions detailed in the User Service Manual (Lucent Technologies
363-208-001, DLP-518).
ED7C734-30 PIU Mounting Procedure
Step 1: Open the cartons to the ARM shelf and the PIU and inspect the contents
especially the connectors and cable assemblies for damage or misalign-
ment.
Step 2: Refer to Figure 2-6 and mount the PIU to the ARM shelf as follows:
a. Using the three screws provided, fasten the PIU hinge to the right
b. Temporarily close the hinged door by finger-tightening the attached
c. Verify that the attached cables drape downward and are not entan-
2-14
Issue 5 May 1997
Left Duct
P103
P104
:
:
side of the ARM shelf from the inside of the shelf.
knurled screw head into the ARM shelf.
gled.
Right Duct
P202
P203
P204