GeNerAL DATA

3.6.7 fan

Device size
Number
Heat sink fan
Speed-variable
NOTICE

3.6.7.1 Switching behaviour of the fan

The fan has different switch-on and switch-off points. The switching point for the switch-
on temperature ① of the fan is adjustable. The switching point for the switch-off temper-
ature ② cannot be changed and is always 5°C below the switch-on temperature.
100
80
60
40
20
0
10
0
Legend
Temperature curve
Setting range for the switch-on temperature
1
Switch-on point
2
Switch-off point
Figure 10:
Switching behaviour of the fan

3.6.7.2 Switching points of the fan

The switching point for the switch-on temperature is adjustable between 0.1°C and
50°C. The default value is 50°C.
50
Destruction of the fan !
► Take care that no foreign substances drop into the fan !
30
20
40
Temperature / °C
07
09
1
50
60
70
10
80
90
100