UL MArKING
• Wiring Terminals marked to indicate proper connections for the power supply, load
• WARNING – The opening of the branch circuit protective device may be an indica-
Devices 07, 09 and 10 / 480V – housing 2 have been evaluated for connecting to DC
voltage, supplied by other KEB inverters to a DC bus capacitance as follows:
Branch Circuit Protection for series S6 housing size 2
I) Class CC fuses; not more than 30000 rms Symmetrical Amperes (SCCR 30kA):
The voltage rating of the external fuses shall be at least equal to the input voltage of the
drives.
Class CC or Class J, not more than 5000 rms Symmetrical Amperes (SCCR 5000):
Class CC not more than 30000 rms Symmetrical Amperes (SCCR 30000):
76
and control circuit.
tion that a fault current has been interrupted. To reduce the risk of fire or electrical
shock, current-carrying parts and other components of the controller should be ex-
amined and replaced if damaged. If burnout of the current element of an overload
relay occurs, the complete overload relay must be replaced.
AVERTISSEMENT – LE DÉCLENCHEMENT DU DISPOSITIF DE PROTECTION
DU CIRCUIT DE DÉRIVATION PEUT ÊTRE DÛ À UNE COUPURE QUI RÉSULTE
D'UN COURANT DE DÉFAUT. POUR LIMITER LE RISQUE D'INCENDIE OU DE
CHOC ÉLECTRIQUE, EXAMINER LES PIÈCES PORTEUSES DE COURANT ET
LES AUTRES ÉLÉMENTS DU CONTRÔLEUR ET LES REMPLACER S'ILS SONT
ENDOMMAGÉS. EN CAS DE GRILLAGE DE L'ÉLÉMENT TRAVERSÉ PAR LE
COURANT DANS UN RELAIS DE SURCHARGE, LE RELAIS TOUT ENTIER DOIT
ÊTRE REMPLACÉ.
cat. No.
Housing
07S6
09S6
02
10S6
cat. No.
Housing
07S6
09S6
02
10S6
cat. No.
Housing
07S6
09S6
02
10S6
cat. No.
Housing
07S6
02
09S6
Min. capacitance
235uF
Dc voltage
680 V
Input Voltage [Vac]
200-230 / 3ph
480 / 3ph
Input Voltage [Vac]
120-230 / 1ph
Max. capacitance
18600 uF
full Load current
3.6 A
5.8 A
8 A
maximum fuse size [A]
6
10
10
maximum fuse size [A]
15
20