PROGRAMMING

Keypad Lock - Password
The password locks or unlocks the blue
buttons on keypad. All PENTEK INTELLIDRIVE
units are shipped from factory with the default
password 7777. It can be changed to any other
1 to 4 digit number. To reset password to a
unique password for unit, unlock keypad (see
below) and follow the keypress sequence
shown in Figure 8 to make the change.
If installer does not press the password button,
then the keypad will automatically lock 60
minutes after the Drive is powered up. The
time out period is adjustable (see Table 9).
To unlock keypad press Password, use
directional arrows to select numeric code and
press ENTER.
NOTICE For more detailed information on
keypad functions, see Figure 2.
Pump Out Operation
Press Pump Out. The Drive will start pump in
a constant speed mode (default 45 Hz). The
pump will run until STOP or Auto Start are
pushed.
Press Auto Start
Verify
"Running Fixed Press"
displayed on screen
Press Enter
Use arrows to
change the value
Press Enter to Save
6568 0512
Figure 13 - Change PSI Setpoint while running
pump.
12
PENTEK IntelliDrive
Owner' s Manual
Setting the Pressure
NOTICE Default pressure setting is 414 kPa.
If this value is changed, adjust tank pressure
accordingly (see Table 7).
There are three ways to change the pressure
setpoint:
• While running the pump
Follow keypress sequence shown in Figure
13 to make desired change. This parameter
allows either Internal or External Setpoint to be
changed, depending on which one is referenced
at the time the change is made.
• Via the PSI Preset
Follow keypress sequence shown in Figure 14 to
make desired change.
• Via the Main Menu (Main Menu/Settings/Set
point/Internal Setpoint)
Press PSI Preset
Press Enter
Use arrows to
change the value
Press Enter to Save
6569 0512
Figure 14 - Change PSI Setpoint using
PSI Preset.
MENU
UNIT OF
PARAMETER
SETTINGS
MEASURE
DEFAULT
Hour Format
Hours
12Hr
Time
mm:ss
1:00 AM
MM/DD/
Date
1/1/12
YYYY
Proportional
2500
Gain
Integration
Milliseconds
500 ms
Time
Derivation
Milliseconds
60 ms
Time
Derivative
120
Limit
Boost
kPa
21 kPa
Differential
Boost Delay
MM:SS
1 Min
Wake Up
kPa
34 kPa
Differential
Wake Delay
MM:SS
15 Sec
Password
HrHr:mm
1 Hr
Time Out
Password
7777
TABLE 9 - MAIN MENU AND PARAMETERS
Table 9 lists all available commands and parameters for the PENTEK INTELLIDRIVE.
PROGRAMMING
VALUE
DESCRIPTION
MIN.
MAX.
12Hr
24Hr
Selects 12 or 24 hour time scale.
Sets current time. Used for time
1
24
stamp in fault log.
Sets current date. Used for date
stamp in fault log.
Sets the PID controller gain. Used
in conjunction with all PID Control
0
10000
parameters to control how fast or
slow the Drive reacts to pressure
changes.
Sets the PID controller integration
time. Used in conjunction with all PID
65000
20 ms
Control parameters to control how
ms
fast or slow Drive reacts to pressure
changes.
Sets PID controller derivation time.
Used in conjunction with all PID
10000
0 ms
Control parameters to control how
ms
fast or slow Drive reacts to pressure
changes.
Sets derivative filter time constant
0
2000
for PID controller.
First part of Boost Process. Pressure
21 kPa 69 kPa
boost that happens before it goes to
Wake Delay.
The time Drive takes to start Boost
30 Sec
5 Min
Process after system has stabilized.
103
Pressure amount below setpoint that
34 kPa
kPa
wakes up Drive.
Second part of the Boost Process.
3 Sec
2 Min
The time it takes to ramp down
pressure during the Boost Process.
Amount of time it takes to lock
1 Min
6 Hr
keypad (after last button is pressed).
0000
9999
Password used to unlock keypad.
PENTEK IntelliDrive
Owner' s Manual
13

Advertisement

Table of Contents
loading

Table of Contents