Checking For Leaks - Manitowoc GROVE GMK7450 Maintenance Manual

Table of Contents

Advertisement

8.10.4
G
O
Maintenance manual
GMK7450

Checking for leaks

When the engine is running, carry out a visual inspection for leaks on the
hydraulic components (tank, pumps, drives, cylinders, control blocks,
valves, pipe and hose lines and connections).
If leaks are detected, check the oil level and top up if necessary;
the oil level , P. 8 - 69.
Risk of accidents from hydraulic oil spraying out!
Never tighten any leaking connections when the system is under pressure.
Change pipes and hose lines only when the system is depressurised.
Risk of environmental damage due to leaking consumables!
Immediately repair leaks in the hydraulic system or have them repaired to
ensure that no hydraulic oil escapes, seeps into the ground or reaches
waterways when the crane is used.
After hydraulic components have been changed
Bleed the hydraulic system;
If damage cannot be rectified immediately or further damage is likely
Notify
Manitowoc Crane Care
crew.
à
Establishing an operational status , P. 8 - 84.
or an authorised GROVE dealer or your repair
3 302 577 en
Maintenance work on the superstructure
8.10 Hydraulic system
W
à
Check
8 - 71