Manitowoc GROVE GMK7450 Maintenance Manual page 181

Table of Contents

Advertisement

Maintenance manual
GMK7450
Checking the connecting terminals
Keep the batteries clean and dry.
Release any dirty connecting terminals (1)
and clean them.
Fasten any loose connecting terminals.
Grease the connecting terminals and poles
lightly with a special battery terminal
grease.
Checking the acid level
Batteries without covers (1) are maintenance-
free.
Remove all covers (1).
The acid level must be above the plates.
If the acid level is too low
Top it up using only distilled water until the
plates are covered.
Tightly screw on all covers (1).
After checking
Close the cover (2) on the battery box.
Attach the selector handle and switch on the
battery master switch (1).
Check the timers on the tachograph and the
auxiliary heater;
Enter the code for the radio;
operating manual .
3 302 577 en
Maintenance work on the carrier
7.16 Electrical system
à
Operating manual .
à
Separate
7 - 109