H
H
Maintenance manual
GMK7450
If you have used a clean receptacle, you can refill the fuel tank with the con-
sumable using a filter.
Otherwise dispose of the consumable properly.
It is not necessary to bleed air from the fuel line when starting this engine.
Start the engine and check for leaks.
Changing the filter
Place a receptacle under the filter (1).
Remove the filter (1).
Fill a new filter (1) with clean consumable
and screw it up (lightly grease the gasket).
Remove the receptacle.
Establishing an operational status
Open the valve (2) – lever parallel to the line.
Close the valve – lever (1) at right angles to
the line.
Remove the receptacle.
3 302 577 en
Maintenance work on the carrier
7.4 Fuel system
7 - 33