Adjusting The Gas Nozzle Clamping Device; Adjusting The Gas Nozzle Clamping Device - Fronius Robacta Reamer X-Line J Operating Instructions Manual

Welding torch cleaning
Hide thumbs Also See for Robacta Reamer X-Line J:
Table of Contents

Advertisement

Adjusting the Gas Nozzle Clamping Device

Adjusting the gas
nozzle clamping
device
An incorrectly set gas nozzle clamping device may damage the cleaning device
and the welding torch.
4
NOTE!
Only clamp the gas nozzle in a central position over the cleaning motor.
34
CAUTION!
When using gas nozzles with an outside diameter of 25 mm (0.98 inches), the gas
nozzle clamping device must not be adjusted - the gas nozzle clamping device has
already been set for the use of gas nozzles with an outside diameter of 25 mm (0.98
inches) as part of the factory calibration.
When using gas nozzles with an outside diameter larger/smaller than 25 mm (0.98
inches), the gas nozzle clamping device must be adjusted before it is started for the
first time and after every device replacement.
Tighten the Allen screws on guide bolts (1) and (2)
NOTE!
Set the clamping device so that no
reaction forces can be transmitted to
the robot.
Only clamp gas nozzles on a cylindrical
surface.
(1)
Loosen the Allen screws on guide
1
(3)
bolts (1) and (2)
(2)
Move the welding torch to the cleaning
2
(4)
position
-
centric to the cleaning motor
Use the adjusting screw (3) to position
3
the clamping device (4) so that the
clamping device is positioned against
the gas nozzle